End Station 422

Description

Carrier departure

  • Sending upwards
  • Carrier is inserted at the bottom of the station
  • Can hold one carrier while waiting for departure
  • Carrier visible while waiting
  • Overload protection

Carrier reception

  • Arrival of the carrier from top
  • Carriers are stopped by central brake before
    approaching the station

Operation 1.0422.x

  • Internal motor valve is closed while carrier is approaching
  • Approaching carrier activates sensor
  • Send slot moves to the right and motor valve opens to release the carrier
  • In stand-by the motor valve is half open
  • Station prevents another carrier to be received whilst a carrier is sitting on the motor valve

Location

This station has to be connected to a diverter.

Technical properties

Material: Sheet-steel case with PVC and ABS parts inside
Colour: Powder painted, white-grey RAL 7035
ESD protected

Optional

  • RFID reader for arrived carriers
  • RFID reader for user to release carriers in secure reception mode
  • RFID reader for user to identify the sender

Additional information

Diameter (mm)

108, 110×2.3, 110×3.2, 132, 160, 200

Control Unit

Keypad 12 keys [H61E], Keypad 19 keys [H61F], Touch Display [H61G]

System

H61

station opening

Below

send / receive

Both

Reception options

Basket Small, Basket Big