Description
Characteristics
- Reads carriers with up to 10 cm distance
- Reads RW and RO tags
- Near field communication (NFC)
- Calibrated for 134 kHz RFID systems
For
- Indentifying individual RFID chipped carriers in the tube system to ensure correct arrival
Installation
- Has to be installed at each sender tube or receiver tube at each station of the system
- To be connected to a H61E or H61F RFID reader card
Technical properties
Resonance frequency: 134.2 kHz
Reading distance: < 100 mm
Operation temperature range: 0 – 50 °C
Size: 10 mm × 10 mm ring
Cable
- Shielded twisted pair (STP), 2 wired with screen
- 2 m length and with connector
- Ready to plug in
Delivery scope
- Antenna ring
- Connector for H61E or H61F
- RFID tags for carriers to be read have to be ordered additionally (1.0628.0.01)
Tube Size | H 61E / MAS-3 / 2m Cable | H 61F / RM2 / 2m cable |
Do 110 | 1.0627.6.20 | 1.0627.6.24 |
Do 132 | 1.0627.7.20 | 1.0627.7.24 |
Do 160 | 1.0627.T.20 | 1.0627.T.24 |