End Station 422

Beschreibung

Carrier departure

  • Sending upwards
  • Carrier is inserted at the bottom of the station
  • Can hold one carrier while waiting for departure
  • Carrier visible while waiting
  • Overload protection

Carrier reception

  • Arrival of the carrier from top
  • Carriers are stopped by central brake before
    approaching the station

Operation 1.0422.x

  • Internal motor valve is closed while carrier is approaching
  • Approaching carrier activates sensor
  • Send slot moves to the right and motor valve opens to release the carrier
  • In stand-by the motor valve is half open
  • Station prevents another carrier to be received whilst a carrier is sitting on the motor valve

Location

This station has to be connected to a diverter.

Technical properties

Material: Sheet-steel case with PVC and ABS parts inside
Colour: Powder painted, white-grey RAL 7035
ESD protected

Optional

  • RFID reader for arrived carriers
  • RFID reader for user to release carriers in secure reception mode
  • RFID reader for user to identify the sender

Zusätzliche Informationen

Durchmesser (mm)

108, 110×2,3, 110×3,2, 132, 160, 200

Bedieneinheit

12 Tasten [H61E], 19 Tasten [H61F], Touch Display [H61G]

System

H61

Öffnung der Station

Unten

Senden / Empfangen

Beides

Empfangsmöglichkeit

Korb klein, Korb groß