Beschreibung
For
- Controlling a H36 system:
- Carrier order
- Blower
- DC power supply
Characteristics
- Controls up to 20 stations (cashiers) at a distance of up to 150 m
- The internal power supply is sufficient for 500 m cable
- Very high sending frequency
Integrated
- Control unit
- Power supply
- Timer module 2 – 270 seconds as total transport time control
- After time out of the timer module two different reactions can be chosen:
- System resets automatically and waits for next job
- System shutdown needs to be reset manually
- 230 V output for blower
- 24 V output for interface-contactor
- Membrane keyboard with:
- Three LEDs: power, busy, error
- Two buttons: blower, reset
- One Power cable with SCHUKO plug
- One fuse for power input
- Short circuit protection for all outputs
Input voltage
110 or 240 VAC
Housing
Protection class: Ip66
Dimensions: 270 mm (h) × 290 mm (w) × 170 mm (d)
Weight: 2.3 kg
Option
- 110 VAC version with US-plug
- Transport counter with reset button (1.1036.0.ZC)
Accessories
- Extension of the control cable length with remote control keyboard (1.1036.0.RC)